MYCHARGEMAN Forum

Members Login
Username 
 
Password 
    Remember Me  
 

Topic: Nama stesen pencawang voltan tinggi TNB..

Post Info
Koperal
Status: Offline
Posts: 50
Date:
Nama stesen pencawang voltan tinggi TNB..
Permalink  
 

PE: Pencawang Elektrik..( Voltage level 11/0.433kv)

PPU: Pencawang Pembahagian Utama..( Voltage level 33/11kv)

SSU: Stesen Suis Utama..( Voltage level 33kv or 11kv)

PMU: Pencawang Masuk Utama..( voltage level 275/132kv)

PGN: Pencawang Grid Nasional..( voltage level 500/275kv)



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 

Satu info yang menarik...

 

Saya rasa PMU dan PPU tu terbalik kedudukannya.. PPU tu besar, Distribution tu.. betul x?



__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

PPU untuk distribution manakala PMU untuk Tranmission station..jadi PMU pencawang yg lebih besar yg memberi bekalan pada PPU distribution..



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 

Ada gak certain tempat, incoming dari PPU. Contohnya di Johor Port,

TNB SITE     | CONSUMER

                    |

PPU              |  PMU I, II (22kV/ 11kV/ 6.6kV) > PE (11kV/0.433kV)

                    |

                    |

 

RALAT:

Maybe di TNB je kot..



__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

Nama Pencawang ni digunakan oleh TNB utk satu malaysia..pada setiap pencawang volatan tinggi..utk bahagian penghantaraan dan pembahagian..



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 

Ada tak sapa2 lagi jumpa kes camni?



__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Lans Koperal
Status: Offline
Posts: 30
Date:
Permalink  
 
aku baru jumpa pasal DISTORTION ni.
macamner tu...........?


__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 

Tentang distortion boleh klik sini untuk download file berkaitan. Boleh bincang perkara ini di topik baru.



__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Staff Sarjan
Status: Offline
Posts: 170
Date:
Permalink  
 

Hanya Perak dgn johor sahaja pakai sistem 22/11 kv..



__________________
ZD
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 

ooo.. macam tu.. kenapa ya?



__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Staff Sarjan
Status: Offline
Posts: 170
Date:
Permalink  
 
mungkin keperluan ketika itu memerlukan 22kv je..(zaman lombong bijih).. Sampai skang masih guna 22 kV sy tidak pasti...

__________________
ZD
Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

yup memang ade lg yg menggunakan bekalan 22kv dari TNB di johor masih digunakan lagi..

ade juge factory2 menggunakan bekalan tersebut..



__________________
Lans Koperal
Status: Offline
Posts: 30
Date:
Permalink  
 


disini mahu share skit pasal keluasan pencawang

kategori P/EJeniskeluasan saiz tanahkeluasan bangunan
    
a) 11/0.400KVa) single chamber14.63m x 14.63m7.67m x 5.72m
b) 22/0.400kVb) Double Chamber17.68m x 14.63m10.67m x 5.72m
 c) Compact substation5.0m x 5.0m2.5m x 2.0m


__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
wa.. bagus.. erm macamana pulak jarak kelegaan (ruang lapang) pencawang?

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Prebet
Status: Offline
Posts: 17
Date:
Permalink  
 

Hanya perak dan johor shaja y mggunakn sistem 6.6kv dan 22 kv ni.di johor bharu sistem 6.6kv n 22kv ni masih byk lg .tp sistem ini akan ditukar kpada 11 n 33 kv scara brperingkat2 bg mmudahkn krja2 senggaran n bg menselaraskn sitem voltan.klau sistem trlalu byk ,akn mlibatkn byk perbezaan dari segi kabel,suis gear,transformer,fius n mcm2 lg.



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
erm.. betul juga ye?

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Prebet
Status: Offline
Posts: 17
Date:
Permalink  
 

Apa prbezaan pencawang pembahagian utama dgn stesen suis utama?



__________________
Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

pencawang pembahagian utama dibekalkan bekalan 33kv kemudian mempunyai power transfomer 30MVA 33/11KV..Pada bahagian 11kv dihantar pada feeder consumer atau PE..

Stesen suis utama dibekalkan bekalan 33kv sahaja kemudian terus kepada feeder keluaran consumer yg menggunakan bekalan 33kv..

Ada juga stesen suis bekalan 11kv sahaja bergnatung pada tempat dan fungsi2 stesen tersebut..

perbezaan yg ketara stesen suis tidak mempunyai Power transfomer manakala pencawang pembahagian utama (PPU) mempunyai power transfomer sebagai bekalan keluaran 11kv kepada consumer dan PE..



__________________
Rekrut
Status: Offline
Posts: 1
Date:
Permalink  
 
info yang sangat menarik,

macam mana nak tau bilangan stesen pencawang voltan tinggi mengikut pecahan kategori?

misalnya, bagi Negeri Kedah: PE: ?, PPU: ?, SSU: ?,PMU: ?, PGN: ?. Negeri Perak: PE: ?, PPU: ?, SSU: ?,PMU: ?, PGN: ?. dan seterusnya?

__________________
Rekrut
Status: Offline
Posts: 3
Date:
Permalink  
 
Boleh terangkan secara ringkas tentang sistem pembahagian dlm tnb....contohnya mula dari transmission line ke ssu,pe,ppu or others....saya amat memerlukan penerangan ini untuk membuat laporan...


__________________
Rekrut
Status: Offline
Posts: 3
Date:
Permalink  
 

apakah fungsi-fungsi pmu,ssu,ppu dan pe?



__________________
 