MYCHARGEMAN Forum

Members Login
Username 
 
Password 
    Remember Me  
 

Topic: Pemula atau inverter?

Post Info
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Pemula atau inverter?
Permalink  
 

Dari segi cekap tenaga, yang mana menjadi pilihan anda?



__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Staff Sarjan
Status: Offline
Posts: 170
Date:
Permalink  
 
frekuensi control..

__________________
ZD
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
cerita sikit pasal F control tu..

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Lans Koperal
Status: Offline
Posts: 30
Date:
Permalink  
 
macamner dengan VS control......... kenapa dah kurang penggunaanya.?

__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
soalan yg bagus...

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Lans Koperal
Status: Offline
Posts: 30
Date:
Permalink  
 
setahu saya Frekuensi control hanya dengan penggunaan INVERTER........
ader ke gadget lain yang boleh mengawal frekuensi selainnya..?

__________________
Staff Sarjan
Status: Offline
Posts: 170
Date:
Permalink  
 
mula-mula dulu pakai, DOL - arus permulaan yang besar

kemudian muncul Star Delta.. Bila sampai 70& full load tukar kepada Delta..

Kemudian muncul soft starter.. Pkai elektronik part.. PCB

Skang ni frekuensi control.. (increase amp & volt ( power motor) dengan menyelaras frekuensi)..lagi smooth, lagi soft, motor tak rosak

__________________
ZD
Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

bile bekalan yg ke motor di kawal Frekuensinye dari inverter..adakah menjejaskan frekuensi pada bekalan di punca masuk inverter..bagaimana input dan output inverter dikawal dan beroperasi?



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
then lagi satu, pstinya inverter akan mewujudkan harmonic current sebab ada PCB atau electronic part. Adakah ini yang dinamakan cekap tenaga?

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Staff Sarjan
Status: Offline
Posts: 170
Date:
Permalink  
 
pakai filter untuk compensate harmonic..Frekuensi di bekalan tidak akan terjejas..semua dikawal secara automatik mode..dia akan increase frekuensi secara gardually sampai la motor mencapai full speed.. semua ni adalah cabang dalam bidang power electronic and drive..

__________________
ZD
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
maknanya kena ada capacitor tambahan?

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Lans Koperal
Status: Offline
Posts: 48
Date:
Permalink  
 
klau motor kawal guna Hz ni dia boleh menjatuhkan power factor kn??

bila Hz diturunkan volt akn turun jgk... bila volt turun amp akan naik... bila amp naik power factor jatuh... hehehe

betul x???



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
wah2... jauhnye... erm,.. kene tanya yang expert gak.. sebab semuanya ada calculation...


__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Lans Koperal
Status: Offline
Posts: 48
Date:
Permalink  
 
tpi 2 le yg AZHAN gtahu & cik sye gtahu...hehehehe bab calculation2 sye xthu sgt....
kena la tnya yg expert

__________________
Lans Koperal
Status: Offline
Posts: 23
Date:
Permalink  
 
iskandar wrote:

macamner dengan VS control......... kenapa dah kurang penggunaanya.?


 Sama ja ada yang pangil VFD dan ada yang pangil VSD...tapi

cara operasinya sama

1. untuk mengawal kelajuan bagi bersesuain dgn kehendak operasi

2.  N=60F/P so semua main dgn F.

 



__________________
Lans Koperal
Status: Offline
Posts: 23
Date:
Permalink  
 
ex-ST wrote:

mula-mula dulu pakai, DOL - arus permulaan yang besar

kemudian muncul Star Delta.. Bila sampai 70& full load tukar kepada Delta..

Kemudian muncul soft starter.. Pkai elektronik part.. PCB

Skang ni frekuensi control.. (increase amp & volt ( power motor) dengan menyelaras frekuensi)..lagi smooth, lagi soft, motor tak rosak


 Tujuan pemakaian starter rasanya bukan mengikut peredaran zaman tetapi keperluan. kerana kalau dilihat sehingga hari ini masih lagi guna DOL, SD tetapi betul dari segi pengunaan ternaga kita hendaklah mengunakan starter mengikut tahap yg kita pelajari tetapi di industri 2300KW pun guna DOL..kenapa..dan HVAC system for compressor masih lagi guna SD.

Contoh pengunaan starter digunapakai diindustri adalah bertujuan keperluan

1. DOL : digunakan bagi yg memelukan dayakilas yg tinggi dan constant load . CTH PUMP, Compressor

2. SD. Digunakan kebiasaannya hanya pada HVAC compressor kerana switching timenya tinggi/kerap.

3. VFD/VSD . Digunakan mengingkut keperluan seperti sesuatu beban itu perlu dikawal kelajuaannya spt. Chiller, Fan dan tidak semua motor boleh dipasang dengan VFD sebagai starter. Motor utk VFD adalah berbeza dari segi bearing type, insulation dan perlu ada themolstat. jadi sekiranya mengunakan motor biasa ianya akan lagi cepat rosak.



__________________
Lans Koperal
Status: Offline
Posts: 23
Date:
Permalink  
 
iskandar wrote:

setahu saya Frekuensi control hanya dengan penggunaan INVERTER........
ader ke gadget lain yang boleh mengawal frekuensi selainnya..?


 yg mengawal frekuensi bukanya Inverter..tetapi IGBT.

Inverter for DC to AC back



__________________
Koperal
Status: Offline
Posts: 51
Date:
Permalink  
 
Apa beza F control dengan VS control?
Cerita sikit kat saya.
saya nak tau juga.

__________________

"Great hopes make great men." Thomas Fuller

316698_114068092028117_110854369016156_71310_7801133_n.jpg

 
Page 1 of 1  sorted by
Quick Reply

Please log in to post quick replies.



Create your own FREE Forum
Report Abuse
Powered by ActiveBoard